{"id":2539,"date":"2026-11-20T09:31:39","date_gmt":"2026-11-20T09:31:39","guid":{"rendered":"https:\/\/altaintegra.com\/?post_type=insight&#038;p=2539"},"modified":"2026-11-20T09:47:17","modified_gmt":"2026-11-20T09:47:17","slug":"circadian-lighting-design-with-tunable-white","status":"publish","type":"insight","link":"https:\/\/altaintegra.com\/th\/insight\/circadian-lighting-design-with-tunable-white\/","title":{"rendered":"Circadian Lighting Design With Tunable White and WELL v2 L03"},"content":{"rendered":"<p class=\"ins-p\">Circadian lighting design considers when light reaches the eye, how much reaches it and what spectrum it contains. Tunable white gives designers independent control of colour temperature and light output. A tunable white scene is assessed for daytime exposure by calculating melanopic equivalent daylight illuminance (melanopic EDI) at eye level, with visual comfort checked alongside it.<\/p>\n<p class=\"ins-p\"><a href=\"https:\/\/v2.wellcertified.com\/\" target=\"_blank\" rel=\"noopener\">WELL v2<\/a> L03 provides a defined workstation criterion for projects pursuing certification. In a deep-plan Jakarta office, people near the windows and people behind tall partitions can receive very different light exposure under the same schedule. The design starts from where people sit, what they look at and when they use the space. That information shows where <a href=\"\/insight\/daylight-calculator-guide\/\">daylight<\/a> is already sufficient and where a tunable white electric layer can close the gap.<\/p>\n<div id=\"rank-math-toc\" class=\"wp-block-rank-math-toc-block\">\n<h2>Table of Contents<\/h2>\n<nav>\n<ul>\n<li><a href=\"#what-tunable-white-is\">Tunable White Channels and Dim-to-Warm<\/a><\/li>\n<li><a href=\"#melanopic-edi\">Melanopic EDI at Eye Level<\/a><\/li>\n<li><a href=\"#circadian-targets\">WELL v2 L03 and the Brown et al. Recommendations<\/a><\/li>\n<li><a href=\"#leed-ies-iso\">Other Standards Related to Circadian Lighting<\/a><\/li>\n<li><a href=\"#office-studies\">Office Studies on Dynamic Lighting<\/a><\/li>\n<li><a href=\"#where-tunable-white-fits\">Spaces That Benefit From Tunable White<\/a><\/li>\n<li><a href=\"#daily-schedule\">A Daily Tunable White Schedule<\/a><\/li>\n<li><a href=\"#schedule-to-performance\">From Lighting Schedule to Occupied Performance<\/a><\/li>\n<li><a href=\"#faq\">FAQ<\/a><\/li>\n<li><a href=\"#alta-integra\">Circadian Lighting Design With ALTA Integra<\/a><\/li>\n<\/ul>\n<\/nav>\n<\/div>\n<h2 class=\"ins-h2\" id=\"what-tunable-white-is\">Tunable White Channels and Dim-to-Warm<\/h2>\n<p class=\"ins-p\">A typical tunable white luminaire mixes warm and cool LED channels. The controls set colour temperature and light output independently within the product&#8217;s operating range. Dim-to-warm products link the two. They become warmer as they dim, which suits a hotel guest room or an evening lounge, according to the <a href=\"https:\/\/www.energy.gov\/eere\/ssl\/understanding-led-color-tunable-products\" target=\"_blank\" rel=\"noopener\">US Department of Energy<\/a>.<\/p>\n<p class=\"ins-p\">Two-channel tunable white systems mix along a straight line between the channels&#8217; colour coordinates, while the blackbody locus is curved. A wide tuning range can bring visible shifts in tint at intermediate settings. Multi-primary products offer more control over that tint, but their performance depends on the product and its programming. For these reasons the spectral power distribution, output, chromaticity and colour rendering of a tunable white product matter at the actual scenes proposed for the project, including low output. A mock-up that includes low dimming levels shows how the system behaves at night, and the colour rendering side is covered in the CRI and R9 guide.<\/p>\n<figure class=\"ins-figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/2026\/11\/circadian-lighting-design-with-tunable-white-202611201554-2.webp\" alt=\"Tunable white illustration with a dimmer dial in front of light that shifts from warm white on the left to cool white on the right\" width=\"968\" height=\"968\" loading=\"lazy\" title=\"\"><figcaption>A tunable white system sets colour temperature, from warm to cool, and light output with separate controls.<\/figcaption><\/figure>\n<h2 class=\"ins-h2\" id=\"melanopic-edi\">Melanopic EDI at Eye Level<\/h2>\n<p class=\"ins-p\">Light reaching the eye helps regulate the timing of the human body clock. The retina&#8217;s intrinsically photosensitive retinal ganglion cells contain melanopsin and also receive input from rods and cones. <a href=\"https:\/\/doi.org\/10.25039\/S026.2018\" target=\"_blank\" rel=\"noopener\">CIE S 026\/E:2018<\/a> defines metrics for the stimulation of all five photoreceptor classes. Melanopic EDI expresses the melanopic stimulus as the illuminance of standard D65 daylight that would provide the same melanopic irradiance. Individual responses also depend on timing, duration, prior light exposure and sensitivity, as <a href=\"https:\/\/doi.org\/10.1371\/journal.pbio.3001571\" target=\"_blank\" rel=\"noopener\">Brown et al. (2022)<\/a> note.<\/p>\n<div class=\"ins-formula\">\n<math display=\"block\"><semantics><mrow><mtext>Melanopic EDI<\/mtext><mo>&#x3D;<\/mo><msub><mi>E<\/mi><mi>v<\/mi><\/msub><mo>&#xD7;<\/mo><mtext>melanopic DER<\/mtext><\/mrow><annotation encoding=\"application\/x-tex\">\\text{Melanopic EDI} = E_{v} \\times \\text{melanopic DER}<\/annotation><\/semantics><\/math><\/p>\n<p class=\"ins-formula-note\">Here E<sub>v<\/sub> is the vertical photopic illuminance at the eye in lux, and melanopic DER is the melanopic daylight efficacy ratio of the light reaching the eye. Melanopic EDI is also in lux.<\/p>\n<\/div>\n<p class=\"ins-p\">D65 has a melanopic DER of 1.0 by definition. The calculation uses the DER of the spectrum actually reaching the eye. When daylight and electric light have different spectra, their contributions are calculated separately at the eye and the melanopic EDI values are added, or the combined spectrum is measured. A luminaire&#8217;s catalogue DER is a starting point for tunable white design. Glazing, furnishings and reflected light influence the spectrum and illuminance received at the seat.<\/p>\n<h3 class=\"ins-h3\" id=\"cooler-scene-less-melanopic\">Why a Cooler Scene Can Deliver Less Melanopic Stimulus<\/h3>\n<p class=\"ins-p\">Brown et al. discuss a 6500 K tunable white LED example with a melanopic DER of 0.83 and a colour-mixed LED example at 4000 K with a DER of 1.4. If each example were the only source and kept its stated DER at the eye, 250 lx melanopic EDI would need about 301 lx vertical photopic illuminance from the 6500 K example or 179 lx from the 4000 K example. These figures describe two specific spectra. A reliable result for a project comes from spectral data at each proposed tunable white setpoint, with vertical illuminance calculated at representative eye positions in the <a href=\"\/insight\/photometric-calculator-guide\/\">photometric calculation<\/a>.<\/p>\n<h2 class=\"ins-h2\" id=\"circadian-targets\">WELL v2 L03 and the Brown et al. Recommendations<\/h2>\n<p class=\"ins-p\">WELL v2 L03 Part 1 is an optional certification feature with a defined workstation assessment. Brown et al. (2022) provide expert consensus recommendations for daily light exposure in healthy adults on regular daytime schedules. The two answer different design questions.<\/p>\n<div class=\"ins-table-wrap\">\n<table class=\"ins-table\">\n<thead>\n<tr>\n<th>Reference<\/th>\n<th>Melanopic EDI at the eye<\/th>\n<th>Application<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Brown et al., daytime<\/td>\n<td>At least 250 lx<\/td>\n<td>At the eye on a vertical plane throughout the daytime, about 1.2 m above the floor for a seated adult<\/td>\n<\/tr>\n<tr>\n<td>Brown et al., evening<\/td>\n<td>At most 10 lx<\/td>\n<td>At the eye, starting at least three hours before bedtime<\/td>\n<\/tr>\n<tr>\n<td>Brown et al., sleep<\/td>\n<td>At most 1 lx<\/td>\n<td>Ambient light at the eye in the sleep environment<\/td>\n<\/tr>\n<tr>\n<td>WELL v2 L03 Part 1, Tier 1, Q2 2025<\/td>\n<td>At least 136 lx, or 109 lx with the qualifying daylight pathway<\/td>\n<td>Daytime workstations<\/td>\n<\/tr>\n<tr>\n<td>WELL v2 L03 Part 1, Tier 2, Q2 2025<\/td>\n<td>At least 250 lx, or 163 lx with the qualifying daylight pathway<\/td>\n<td>Daytime workstations<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"ins-p ins-table-caption\">Brown et al., PLOS Biology, 2022. WELL v2 Q2 2025, Feature L03 Part 1.<\/p>\n<p class=\"ins-p\">The WELL workstation criteria use a vertical plane at eye level, 45 cm above the work plane, for at least four hours beginning no later than noon. The lower thresholds apply when the project also achieves L05 Part 1 or L06 Part 1. The WELL edition and documentation requirements that apply to a given project still need confirming before the table is used for certification. The workstation criterion can be met with fixed-spectrum electric lighting, so tunable white is a project choice that WELL does not require.<\/p>\n<p class=\"ins-p\">The evening and sleep rows in the table come from Brown et al. only, since both WELL rows cover daytime exposure at workstations. For hotels and care settings, the evening and sleep figures serve as research context for guest or resident scenes, alongside actual sleep schedules, staff tasks and safe circulation. Spaces serving children, older adults or shift workers need application-specific design decisions, as the <a href=\"https:\/\/www.cie.co.at\/publications\/cie-position-statement-integrative-lighting-recommending-proper-light-proper-time-3rd\" target=\"_blank\" rel=\"noopener\">CIE position statement on integrative lighting<\/a> also notes.<\/p>\n<h2 class=\"ins-h2\" id=\"leed-ies-iso\">Other Standards Related to Circadian Lighting<\/h2>\n<div class=\"ins-table-wrap\">\n<table class=\"ins-table\">\n<thead>\n<tr>\n<th>Reference<\/th>\n<th>What it covers<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>LEED v5 ID+C, EQc2 Occupant Experience, Option 5 Lighting Environment<\/td>\n<td>Solar glare control, quality electric lighting, proximity to windows and daylight simulation are distinct paths. The electric-light path addresses glare and colour rendering. LEED v4.1 ID+C projects use the Interior Lighting and Daylight credits.<\/td>\n<\/tr>\n<tr>\n<td>ANSI\/IES RP-46-25 and ANSI\/IES RP-1-24<\/td>\n<td>RP-46-25 guides the application of light-and-health research in daytime interiors such as offices and schools. RP-1-24 covers office lighting quality, including glare, displays and controls.<\/td>\n<\/tr>\n<tr>\n<td>ISO\/CIE 8995-1:2025<\/td>\n<td>Requirements for indoor workplace lighting quantity and quality, including visual comfort, performance and safety, with recommendations for integrative lighting.<\/td>\n<\/tr>\n<tr>\n<td>ANSI\/IES TM-30-24+E1<\/td>\n<td>Evaluates how a light source renders colours. The LEED v5 ID+C Quality Electric Lighting path references the TM-30-20 edition.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"ins-p ins-table-caption\">Sources are listed at the end of the article. The LEED v5 wording follows the USGBC ID+C rating system, November 2025 edition.<\/p>\n<p class=\"ins-p\">In an office fit-out these checks belong in the same early study. A tunable white scene can meet its eye-level exposure target and still cause glare on screens, and the same shade that improves screen visibility can reduce daylight at nearby workstations. Modelling those conditions together comes before the tunable white output is set. The credit side is explained in the <a href=\"\/insight\/leed-lighting-strategy-v5-v4-1\/\">LEED lighting strategy guide<\/a>.<\/p>\n<h2 class=\"ins-h2\" id=\"office-studies\">Office Studies on Dynamic Lighting<\/h2>\n<p class=\"ins-p\">In a crossover study in an operational office, <a href=\"https:\/\/doi.org\/10.1016\/j.buildenv.2022.108844\" target=\"_blank\" rel=\"noopener\">Kompier et al. (2022)<\/a> compared two dynamic lighting scenarios with a constant reference. The researchers found subtle differences in self-reported sleepiness and no detected improvement in task performance. Participants rated visual comfort higher under the constant scenario. A dynamic or tunable white office schedule needs testing with the people who work under it, particularly where luminaires or windows are in their field of view.<\/p>\n<p class=\"ins-p\">A 2025 office case study in <a href=\"https:\/\/doi.org\/10.1080\/15502724.2024.2434976\" target=\"_blank\" rel=\"noopener\">LEUKOS<\/a> used wearable light sensors to examine personal exposure during a post-occupancy evaluation. It shows that a spot reading at a desk and a person&#8217;s exposure over the day answer different questions, because people move between desks, meeting rooms, outdoor spaces and other settings. After handover, occupant feedback about glare, scene use and overrides shows where the schedule needs adjustment. A voluntary wearable study adds value when the project needs to understand exposure across the whole day.<\/p>\n<p class=\"ins-p\">Evening responses vary as well. <a href=\"https:\/\/doi.org\/10.1073\/pnas.1901824116\" target=\"_blank\" rel=\"noopener\">Phillips et al. (2019)<\/a> found substantial variation between individuals in melatonin suppression under controlled evening light. In spaces where people wind down before sleep, accessible dimming and low-output local lighting let them adjust the scene to their needs.<\/p>\n<figure class=\"ins-figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/2026\/11\/circadian-lighting-design-with-tunable-white-202611201554-3.webp\" alt=\"Illustrative 24-hour chart of melatonin and cortisol over a lake landscape that moves from night through sunrise and daylight to sunset\" width=\"1600\" height=\"353\" loading=\"lazy\" title=\"\"><figcaption>An illustration of melatonin and cortisol across 24 hours. Melatonin peaks at night and cortisol in the morning, and the timing differs from person to person.<\/figcaption><\/figure>\n<h2 class=\"ins-h2\" id=\"where-tunable-white-fits\">Spaces That Benefit From Tunable White<\/h2>\n<div class=\"ins-table-wrap\">\n<table class=\"ins-table\">\n<thead>\n<tr>\n<th>Space<\/th>\n<th>Main consideration<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Deep-plan offices<\/td>\n<td>Daylight and electric light assessed at representative eye positions and view directions, with blinds in typical positions. A fixed-spectrum solution with suitable distribution and dimming is tested before spectral tuning is chosen, and tunable white is used where changing activities or schedules justify it.<\/td>\n<\/tr>\n<tr>\n<td>Schools<\/td>\n<td>Intuitive presets for teachers and a straightforward way to adjust output. In a US DOE trial in three Texas classrooms, teachers used presets more often than they adjusted colour. The estimated 58% reduction was in input power compared with the previous fluorescent system.<\/td>\n<\/tr>\n<tr>\n<td>Senior care<\/td>\n<td>Daytime exposure, resident comfort, staff visibility and overnight wayfinding considered together. A DOE pilot at the ACC Care Center estimated 68% corridor lighting energy savings compared with the previous fluorescent system, including automatic dimming. Its small scale limits conclusions about resident health outcomes.<\/td>\n<\/tr>\n<tr>\n<td>Hotel guest rooms<\/td>\n<td>An easy choice between a low-output tunable white evening scene and brighter task lighting for guests, with discreet lighting for getting to the bathroom at night.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"ins-p ins-table-caption\">US DOE GATEWAY reports on the Carrollton-Farmers Branch classrooms (2017) and the ACC Care Center (2016). Hotel guidance follows the evening and sleep figures in Brown et al. (2022).<\/p>\n<h2 class=\"ins-h2\" id=\"daily-schedule\">A Daily Tunable White Schedule<\/h2>\n<p class=\"ins-p\">A daily tunable white schedule works best as a melanopic EDI target at the eye for each period of the day, with the colour temperature and output of each luminaire group set to reach it. The kelvin values follow from the calculation, because the same CCT can carry a very different melanopic DER depending on the product. Because Brown et al. give their figures as melanopic EDI at the eye, a schedule written in the same unit can be checked directly against the lighting calculation and against measurements at commissioning.<\/p>\n<div class=\"ins-table-wrap\">\n<table class=\"ins-table\">\n<thead>\n<tr>\n<th>Period<\/th>\n<th>Aim<\/th>\n<th>Melanopic EDI at the eye<\/th>\n<th>Typical setting<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Morning to midday<\/td>\n<td>The daytime dose, including the WELL window<\/td>\n<td>At least 250 lx, held for at least four hours beginning by noon for WELL L03 Tier 2<\/td>\n<td>Cooler white at higher output, topped up around the available daylight<\/td>\n<\/tr>\n<tr>\n<td>Afternoon<\/td>\n<td>Daytime level held while people are still working<\/td>\n<td>At least 250 lx through the daytime (Brown et al., 2022)<\/td>\n<td>Neutral white, adjusted as daylight changes<\/td>\n<\/tr>\n<tr>\n<td>Evening, from at least 3 hours before bedtime<\/td>\n<td>Less stimulation in homes, hotels and care settings<\/td>\n<td>At most 10 lx<\/td>\n<td>Warm white at low output<\/td>\n<\/tr>\n<tr>\n<td>Night and sleep<\/td>\n<td>A dark sleep environment<\/td>\n<td>At most 1 lx, ambient<\/td>\n<td>Lights off, with low night lighting only where safety needs it<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"ins-p ins-table-caption\">Targets from Brown et al. (2022) and WELL v2 L03 Part 1. Settings are indicative and are confirmed by calculation for each project.<\/p>\n<p class=\"ins-p\">The ACC Care Center trial gives a real example of such a schedule. Its corridor was set to 6500 K at 66% output in the morning, 4000 K at 66% in the afternoon and 2700 K at 20% at night, and amber LED night lighting was built into the handrails (<a href=\"https:\/\/www.energy.gov\/sites\/prod\/files\/2016\/09\/f33\/2016_gateway-acc_brief.pdf\" target=\"_blank\" rel=\"noopener\">US DOE, 2016<\/a>). An office tunable white schedule usually covers only the first two periods, since most offices are empty by the evening. In Jakarta the length of the day changes little through the year, which keeps the daytime schedule stable from month to month.<\/p>\n<h2 class=\"ins-h2\" id=\"schedule-to-performance\">From Lighting Schedule to Occupied Performance<\/h2>\n<p class=\"ins-p\">For an office in Jakarta, the work begins with the seating plan and the tasks people perform. Seated eye-level exposure and horizontal task illuminance are modelled for window-side and interior seats, together with likely shade positions and sightlines to windows, screens and luminaires. Daylight gaps are then filled by a tunable white layer with a distribution that delivers useful light to the eyes while keeping visual comfort. On a WELL project, the applicable electric-light pathway is documented, and combined daylight and electric light are assessed separately to understand the occupied experience.<\/p>\n<p class=\"ins-p\">Daytime tunable white scenes follow occupancy and available daylight. In guestrooms or care settings, evening and night scenes follow the users&#8217; actual schedules and safety needs, and CCT and output are chosen after the product spectra and the room have been evaluated. Commissioning verifies representative eye-level and task-plane conditions, confirms that the tunable white scenes dim as intended and shows occupants or staff how to override the controls. After handover, the useful questions are which scenes people use, when they override them and whether the lighting is comfortable for screen work, reading and moving through the space.<\/p>\n<h2 class=\"ins-h2\" id=\"faq\">FAQ<\/h2>\n<div class=\"ins-faq\">\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>What is tunable white lighting?<\/strong><\/p>\n<p class=\"ins-faq-a\">Tunable white lighting allows the colour temperature of white light to be adjusted independently from its intensity. Standard builds mix a warm white LED channel near 2700 K with a cool white channel of 5000 to 6500 K. Dim-to-warm products tie both parameters together and warm as they dim, typically from 2700-3000 K at full output down to as low as 1800 K.<\/p>\n<\/div>\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>What is melanopic EDI, and how is it calculated at eye level?<\/strong><\/p>\n<p class=\"ins-faq-a\">Melanopic EDI expresses the melanopic stimulus reaching the eye as the illuminance of standard D65 daylight that would produce the same melanopic irradiance. It equals the vertical photopic illuminance at the eye multiplied by the melanopic daylight efficacy ratio (DER) of the light reaching that point. For example, 300 lx vertically with a melanopic DER of 0.83 gives 249 lx melanopic EDI. For a mix of daylight and electric light, the combined spectrum is used, or the separately calculated contributions are added.<\/p>\n<\/div>\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>Does WELL v2 L03 require tunable white lighting?<\/strong><\/p>\n<p class=\"ins-faq-a\">No. WELL v2 L03 Part 1 specifies daytime workstation light levels and assessment conditions. A fixed-spectrum electric lighting system can meet the criterion if it delivers the applicable performance. Tunable white is useful when the same space needs different spectra and output levels for different times or activities.<\/p>\n<\/div>\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>How much melanopic EDI does WELL v2 L03 require at office workstations?<\/strong><\/p>\n<p class=\"ins-faq-a\">In WELL v2 Q2 2025, L03 Part 1 calls for at least 136 lx melanopic EDI for Tier 1 or 250 lx for Tier 2. If the project also achieves L05 Part 1 or L06 Part 1, the corresponding thresholds are 109 lx and 163 lx. The light is evaluated on a vertical plane 45 cm above the work plane for at least four hours beginning no later than noon, and the WELL edition applicable to the project should be confirmed.<\/p>\n<\/div>\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>Does 6500 K lighting always deliver more melanopic EDI?<\/strong><\/p>\n<p class=\"ins-faq-a\">No. At the same eye-level photopic illuminance, the source with the higher melanopic DER delivers more melanopic EDI. In the examples above, at 300 lx vertically, the 6500 K source delivers 249 lx melanopic EDI while the 4000 K source delivers 420 lx. These values describe the two example spectra, so product-specific data and the installed scenes at eye level decide the real result.<\/p>\n<\/div>\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>Can a standard lux meter measure melanopic EDI?<\/strong><\/p>\n<p class=\"ins-faq-a\">A standard lux meter measures photopic illuminance only. Melanopic EDI is calculated by pairing that reading with the melanopic DER of the spectrum reaching the eye. A calibrated spectral instrument with suitable measurement software can determine the metric from the measured spectrum, and certification follows the applicable verification protocol.<\/p>\n<\/div>\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>Who provides tunable white lighting design consulting in Jakarta?<\/strong><\/p>\n<p class=\"ins-faq-a\">ALTA Integra provides Special Lighting design consulting in Jakarta and across Indonesia, including tunable white and circadian lighting. The scope is described on the <a href=\"\/services\/lighting-designer\/\">lighting designer service page<\/a>.<\/p>\n<\/div>\n<\/div>\n<h2 class=\"ins-h2\" id=\"alta-integra\">Circadian Lighting Design With ALTA Integra<\/h2>\n<p class=\"ins-p\">ALTA Integra provides lighting design consultancy in Jakarta and across Indonesia. The scope can include daylight and electric-light modelling, eye-level spectral measurement, tunable white scene programming and commissioning. On a WELL project, the target pathway is best identified early, so the design team can coordinate glazing, shading, workstation layout and lighting controls before luminaires are selected.<\/p>\n<h2 class=\"ins-h2\" id=\"sources\">Sources<\/h2>\n<ol class=\"ins-sources\">\n<li><a href=\"https:\/\/doi.org\/10.25039\/S026.2018\" target=\"_blank\" rel=\"noopener\">CIE, CIE S 026\/E:2018, System for Metrology of Optical Radiation for ipRGC-Influenced Responses to Light<\/a>.<\/li>\n<li><a href=\"https:\/\/www.cie.co.at\/publications\/cie-position-statement-integrative-lighting-recommending-proper-light-proper-time-3rd\" target=\"_blank\" rel=\"noopener\">CIE, Position Statement on Integrative Lighting, 3rd edition, 2024<\/a>.<\/li>\n<li><a href=\"https:\/\/doi.org\/10.1371\/journal.pbio.3001571\" target=\"_blank\" rel=\"noopener\">Brown, T. M., et al., Recommendations for daytime, evening, and nighttime indoor light exposure to best support physiology, sleep, and wakefulness in healthy adults, PLOS Biology, 2022<\/a>.<\/li>\n<li><a href=\"https:\/\/v2.wellcertified.com\/\" target=\"_blank\" rel=\"noopener\">International WELL Building Institute, WELL v2, Feature L03 Part 1, Q2 2025<\/a>. See also the <a href=\"https:\/\/www.scielo.br\/j\/ac\/a\/c64wjGRCpTngB7nYvWXbQwK\/?lang=pt\" target=\"_blank\" rel=\"noopener\">published reproduction of the Q2 2025 thresholds<\/a>.<\/li>\n<li><a href=\"https:\/\/webstore.ansi.org\/standards\/iesna\/ansiiesrp4625\" target=\"_blank\" rel=\"noopener\">IES, ANSI\/IES RP-46-25, Supporting the Physiological and Behavioral Effects of Lighting in Interior Daytime Environments<\/a>.<\/li>\n<li><a href=\"https:\/\/ies.org\/products\/recommended-practice-lighting-office-spaces\/\" target=\"_blank\" rel=\"noopener\">IES, ANSI\/IES RP-1-24, Lighting Office Spaces<\/a>.<\/li>\n<li><a href=\"https:\/\/www.iso.org\/standard\/76342.html\" target=\"_blank\" rel=\"noopener\">ISO\/CIE 8995-1:2025, Light and lighting, Lighting of work places, Part 1: Indoor<\/a>.<\/li>\n<li><a href=\"https:\/\/www.energy.gov\/eere\/ssl\/understanding-led-color-tunable-products\" target=\"_blank\" rel=\"noopener\">US Department of Energy, Understanding LED Color-Tunable Products<\/a>.<\/li>\n<li><a href=\"https:\/\/ies.org\/products\/technical-memorandum-ies-method-for-evaluating-light-source-color-rendition\/\" target=\"_blank\" rel=\"noopener\">IES, ANSI\/IES TM-30-24+E1, Method for Evaluating Light Source Color Rendition<\/a>.<\/li>\n<li><a href=\"https:\/\/www.usgbc.org\/sites\/default\/files\/2025-10\/LEED%20v5%20ID%2BC%20Rating%20System_November%202025_clean.pdf\" target=\"_blank\" rel=\"noopener\">US Green Building Council, LEED v5 ID+C Rating System, November 2025 edition<\/a>, EQc2, Option 5.<\/li>\n<li><a href=\"https:\/\/www.usgbc.org\/leed\/v41\" target=\"_blank\" rel=\"noopener\">US Green Building Council, LEED v4.1 rating system resources<\/a>.<\/li>\n<li><a href=\"https:\/\/doi.org\/10.1073\/pnas.1901824116\" target=\"_blank\" rel=\"noopener\">Phillips, A. J. K., et al., High sensitivity and interindividual variability in the response of the human circadian system to evening light, PNAS, 2019<\/a>.<\/li>\n<li><a href=\"https:\/\/doi.org\/10.1016\/j.buildenv.2022.108844\" target=\"_blank\" rel=\"noopener\">Kompier, M. E., et al., Contrasting dynamic light scenarios in an operational office, Building and Environment, 2022<\/a>.<\/li>\n<li><a href=\"https:\/\/doi.org\/10.1080\/15502724.2024.2434976\" target=\"_blank\" rel=\"noopener\">Hartmeyer et al., Post-Occupancy Evaluation of Office Lighting, What Can We Learn from Light-Dosimetry?, LEUKOS, 2025<\/a>.<\/li>\n<li><a href=\"https:\/\/www.energy.gov\/sites\/default\/files\/2017\/10\/f37\/2017_gateway_tuning-classroom_0.pdf\" target=\"_blank\" rel=\"noopener\">US Department of Energy, Evaluating Tunable LED Lighting in Three Texas Classrooms, 2017<\/a>.<\/li>\n<li><a href=\"https:\/\/www.energy.gov\/sites\/prod\/files\/2016\/09\/f33\/2016_gateway-acc.pdf\" target=\"_blank\" rel=\"noopener\">US Department of Energy, Tuning the Light in Senior Care, 2016<\/a>.<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>A practical guide to measuring light at eye level, designing for WELL v2 L03 and deciding where tunable white adds value.<\/p>\n","protected":false},"author":0,"featured_media":2807,"template":"","meta":{"_acf_changed":false,"footnotes":""},"subsector":[],"stream":[108],"class_list":["post-2539","insight","type-insight","status-publish","has-post-thumbnail","hentry","stream-knowledge"],"acf":[],"_links":{"self":[{"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/insights\/2539","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/insights"}],"about":[{"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/types\/insight"}],"version-history":[{"count":15,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/insights\/2539\/revisions"}],"predecessor-version":[{"id":2810,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/insights\/2539\/revisions\/2810"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/media\/2807"}],"wp:attachment":[{"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/media?parent=2539"}],"wp:term":[{"taxonomy":"subsector","embeddable":true,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/subsector?post=2539"},{"taxonomy":"stream","embeddable":true,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/stream?post=2539"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}