{"id":833,"date":"2026-07-15T09:40:11","date_gmt":"2026-07-15T09:40:11","guid":{"rendered":"https:\/\/altaintegra.com\/insight\/noise-control-consultation-solving-noise-leakage-2\/"},"modified":"2026-11-17T10:49:50","modified_gmt":"2026-11-17T10:49:50","slug":"zincalum-roof-noise-leakage-case-study","status":"publish","type":"insight","link":"https:\/\/altaintegra.com\/th\/insight\/zincalum-roof-noise-leakage-case-study\/","title":{"rendered":"Tracing Noise Leakage to a Roof: A Karaoke Venue Case Study"},"content":{"rendered":"<p class=\"ins-p\">When a karaoke venue in Pamanukan was disturbing neighbouring housing and a nearby hotel, the obvious suspects were walls and doors. Measurement found otherwise: this was roof noise leakage, and the largest single path was the <strong>zincalum roof<\/strong>, radiating 99 dB at its surface, with the escaping energy concentrated at low frequencies: the range lightweight materials block least effectively. That single finding redirected the entire solution, and it is the reason the case is worth reading.<\/p>\n<p class=\"ins-p\">Measurements were taken on 26 January 2010 between 5 and 6 p.m. The target was to bring leakage within 55 dB, the applicable threshold under Indonesian noise regulation for a residential setting.<\/p>\n<div id=\"rank-math-toc\" class=\"wp-block-rank-math-toc-block\">\n<h2>Table of Contents<\/h2>\n<nav>\n<ul>\n<li><a href=\"#measured-leakage-and-projected-performance-after-treatment\">Measured Leakage, and Projected Performance After Treatment<\/a><\/li>\n<li><a href=\"#reading-the-measurements\">Reading the Measurements<\/a><\/li>\n<li><a href=\"#from-99-db-at-the-zincalum-roof-to-a-158-metre-disturbance-radius\">From 99 dB at the Zincalum Roof to a 158-Metre Disturbance Radius<\/a><\/li>\n<li><a href=\"#the-recommended-solution\">The Recommended Solution<\/a><\/li>\n<li><a href=\"#why-the-method-outlasts-the-project\">Why the Method Outlasts the Project<\/a><\/li>\n<li><a href=\"#faq\">FAQ<\/a><\/li>\n<li><a href=\"#related-work\">Related Roof Noise Leakage Insights<\/a><\/li>\n<\/ul>\n<\/nav>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/2026\/07\/01_pengukuran-akustik2_jpg.webp\" alt=\"Acoustic measurement at a karaoke venue with a zincalum roof causing noise leakage\" title=\"\"><\/p>\n<h2 class=\"ins-h2\" id=\"measured-leakage-and-projected-performance-after-treatment\">Measured Leakage, and Projected Performance After Treatment<\/h2>\n<div class=\"ins-table-wrap\">\n<table class=\"ins-table\">\n<thead>\n<tr>\n<th>Measurement point<\/th>\n<th>Measured (Jan 2010)<\/th>\n<th>Projected after treatment<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Speaker<\/td>\n<td>120 dB<\/td>\n<td>120 dB<\/td>\n<\/tr>\n<tr>\n<td>Middle hall<\/td>\n<td>110\u2013115 dB<\/td>\n<td>110\u2013115 dB<\/td>\n<\/tr>\n<tr>\n<td>Ceiling below zincalum roofing<\/td>\n<td>106 dB<\/td>\n<td>94 dB<\/td>\n<\/tr>\n<tr>\n<td>Zincalum roofing surface<\/td>\n<td>99 dB<\/td>\n<td>89 dB<\/td>\n<\/tr>\n<tr>\n<td>Concrete roofing<\/td>\n<td>88 dB<\/td>\n<td>75 dB<\/td>\n<\/tr>\n<tr>\n<td>Rear hallway<\/td>\n<td>80\u201385 dB<\/td>\n<td>68 dB<\/td>\n<\/tr>\n<tr>\n<td>Left hallway<\/td>\n<td>80 dB<\/td>\n<td>69 dB<\/td>\n<\/tr>\n<tr>\n<td>Hotel parking<\/td>\n<td>78 dB<\/td>\n<td>66 dB<\/td>\n<\/tr>\n<tr>\n<td>Front parking<\/td>\n<td>75 dB<\/td>\n<td>60 dB<\/td>\n<\/tr>\n<tr>\n<td>Kitchen (door closed)<\/td>\n<td>70 dB<\/td>\n<td>58 dB<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"ins-p ins-table-caption\"><strong>The right-hand column is only projected.<\/strong> These are the estimated results of applying the recommended treatment, calculated at design stage. No post-implementation measurement is recorded in the source.<\/p>\n<h2 class=\"ins-h2\" id=\"reading-the-measurements\">Reading the Measurements<\/h2>\n<p class=\"ins-p\">Two things stand out in the measured column. The zincalum roof at 99 dB is the highest reading outside the hall itself, higher than any hallway, wall or door position. And the ceiling immediately below that roofing sits at 106 dB, confirming the energy is reaching the roof rather than escaping elsewhere and being picked up there.<\/p>\n<p class=\"ins-p\">Zincalum roofing is thin, lightweight <a href=\"https:\/\/en.wikipedia.org\/wiki\/Soundproofing\" target=\"_blank\" rel=\"noopener\">profiled steel<\/a>. Its mass per unit area is low, and transmission loss through a single-leaf element depends heavily on mass, which is why it performs poorly at exactly the low frequencies a karaoke system produces most of. The venue&#8217;s loudest surface was, in effect, its lightest.<\/p>\n<h2 class=\"ins-h2\" id=\"from-99-db-at-the-zincalum-roof-to-a-158-metre-disturbance-radius\">From 99 dB at the Zincalum Roof to a 158-Metre Disturbance Radius<\/h2>\n<p class=\"ins-p\">From the measured levels and the low-frequency concentration, disturbance above the 55 dB threshold was estimated to remain audible up to roughly <strong>158 metres<\/strong> from the venue (well beyond its own boundary), which accounts directly for complaints from both residents and hotel guests. Converting a surface measurement into a disturbance radius is what turns an acoustic reading into something a venue owner and a neighbour can both understand.<\/p>\n<h2 class=\"ins-h2\" id=\"the-recommended-solution\">The Recommended Solution<\/h2>\n<p class=\"ins-p\">Two interventions, both aimed at the identified path rather than distributed around the building. The first replaces the zincalum roof with a concrete deck and so addresses the largest single leakage surface by substituting a high-mass element for a low-mass one. The second adds high-mass sound insulation material to block remaining low-frequency transmission through the rest of the structure.<\/p>\n<p class=\"ins-p\">Both work through the same mechanism: mass, because that is what the diagnosis called for. Low-frequency transmission through a lightweight element is a mass problem, and absorption, sealing or barrier treatment would not have addressed it. Projected results put the disturbance radius at roughly <strong>45 metres<\/strong>, down from 158 (a reduction of more than two-thirds).<\/p>\n<h2 class=\"ins-h2\" id=\"why-the-method-outlasts-the-project\">Why the Method Outlasts the Project<\/h2>\n<p class=\"ins-p\">The transferable point is not the roof. It is that the leakage path was identified by measurement before anything was specified. A generic noise-reduction package for an entertainment venue would have addressed walls, doors and glazing (all of which measured lower than the roof) and would have improved the situation marginally at considerable cost.<\/p>\n<p class=\"ins-p\">Identifying which surface, which frequency range and which path is responsible, then applying a targeted structural and material fix, remains how ALTA Integra approaches entertainment-venue and mixed-use noise control through its <a href=\"\/services\/acoustic-consultant\/\">acoustic engineering and design<\/a> practice. It follows the same measurement-first logic set out in our article on <a href=\"\/insight\/acoustic-noise-measurement\/\">acoustic noise measurement<\/a>.<\/p>\n<h2 class=\"ins-h2\" id=\"faq\">FAQ<\/h2>\n<div class=\"ins-faq\">\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>What caused the noise leakage at this venue?<\/strong><\/p>\n<p class=\"ins-faq-a\">The zincalum roof, measuring 99 dB at its surface, is the highest reading outside the hall itself. Zincalum is thin, lightweight profiled steel with low mass per unit area, so it performs poorly against exactly the low-frequency energy a karaoke system produces most of.<\/p>\n<\/div>\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>What solution was recommended?<\/strong><\/p>\n<p class=\"ins-faq-a\">Replacing the zincalum roof with a concrete deck, and adding high-mass sound insulation material to block remaining low-frequency transmission. Both work through mass, because low-frequency transmission through a lightweight element is a mass problem that absorption or sealing would not address.<\/p>\n<\/div>\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>How much did the disturbance radius improve?<\/strong><\/p>\n<p class=\"ins-faq-a\">The estimated radius of disturbance above the 55 dB threshold was projected to fall from about 158 metres to about 45 metres. That is a reduction of more than two-thirds. These are design-stage projections rather than post-implementation measurements.<\/p>\n<\/div>\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>Why was 55 dB the target?<\/strong><\/p>\n<p class=\"ins-faq-a\">It was the applicable compliance threshold under Indonesian noise regulation for the venue&#8217;s residential surroundings. Indonesian noise limits are set by area designation, so the applicable figure depends on the zoning around a given site.<\/p>\n<\/div>\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>Is this measurement-led approach still used?<\/strong><\/p>\n<p class=\"ins-faq-a\">Yes. Identifying the specific leakage path and frequency range through on-site measurement, then recommending a targeted structural fix rather than a generic package, remains the core method for entertainment-venue and karaoke noise control.<\/p>\n<\/div>\n<\/div>\n<p><!--alta-seo-block--><\/p>\n<h2 id=\"related-work\" class=\"ins-h2\">Related Roof Noise Leakage Insights and Project Work<\/h2>\n<p class=\"ins-p\">Further Roof Noise Leakage material from ALTA Integra: related technical insights, and the built projects where this engineering was applied.<\/p>\n<ul class=\"ins-related\">\n<li><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/2026\/07\/01_measurement-fix_jpg.webp\" alt=\"Acoustic Noise Measurement: Turning a Complaint Into Data You Can Design Against : related roof noise leakage work by ALTA Integra\" loading=\"lazy\" title=\"\"> <strong>Insight:<\/strong> <a href=\"https:\/\/altaintegra.com\/insight\/acoustic-noise-measurement\/\">Acoustic Noise Measurement: Turning a Complaint Into Data You Can Design Against<\/a> . Without measurement, a noise fix is a guess, and guesses in acoustics tend to be either over-specified or aimed at the wrong path entirely.<\/li>\n<li><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/2026\/07\/01_subway-tunnel_jpg.webp\" alt=\"Structure-Borne vs Airborne Noise: How to Diagnose the Transmission Path in a Building : related roof noise leakage work by ALTA Integra\" loading=\"lazy\" title=\"\"> <strong>Insight:<\/strong> <a href=\"https:\/\/altaintegra.com\/insight\/structure-borne-noise-vs-airborne-noise\/\">Structure-Borne vs Airborne Noise: How to Diagnose the Transmission Path in a Building<\/a> . Footsteps sound airborne but are not. Diagnosing which path a noise takes is what separates an effective mitigation budget from an expensive guess.<\/li>\n<li><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/2026\/07\/01_bedroom-and-concert-hall-min-1024x545-1_png.webp\" alt=\"Controlling Reverberation and Echo: Measuring RT60 in Each Frequency Band : related roof noise leakage work by ALTA Integra\" loading=\"lazy\" title=\"\"> <strong>Insight:<\/strong> <a href=\"https:\/\/altaintegra.com\/insight\/sabine-formula-controlling-reverberation\/\">Controlling Reverberation and Echo: Measuring RT60 in Each Frequency Band<\/a> . A room can hit a textbook average RT60 and still sound wrong, because the average hides what each frequency is doing.<\/li>\n<li><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/bomus-karawang-2.png\" alt=\"Bomus Karaoke Karawang : related roof noise leakage work by ALTA Integra\" loading=\"lazy\" title=\"\"> <strong>Project:<\/strong> <a href=\"https:\/\/altaintegra.com\/project\/bomus-karawang\/\">Bomus Karaoke Karawang<\/a> , acoustic isolation, AV, and lighting design across a multi-room karaoke venue in Karawang.<\/li>\n<li><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/rs-pik.jpg\" alt=\"Pantai Indah Kapuk Hospital : related roof noise leakage work by ALTA Integra\" loading=\"lazy\" title=\"\"> <strong>Project:<\/strong> <a href=\"https:\/\/altaintegra.com\/project\/pik-hospital\/\">Pantai Indah Kapuk Hospital<\/a> : Construction-noise barriers protecting an active hospital (predictive design, on-site measurement, eco-friendly materials).<\/li>\n<\/ul>\n<p><!--\/alta-seo-block--><\/p>\n","protected":false},"excerpt":{"rendered":"<p>When a karaoke venue in Pamanukan was disturbing neighb [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":834,"template":"","meta":{"_acf_changed":false,"footnotes":""},"subsector":[],"stream":[2],"class_list":["post-833","insight","type-insight","status-publish","has-post-thumbnail","hentry","stream-site-observation"],"acf":[],"_links":{"self":[{"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/insights\/833","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/insights"}],"about":[{"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/types\/insight"}],"version-history":[{"count":7,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/insights\/833\/revisions"}],"predecessor-version":[{"id":2742,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/insights\/833\/revisions\/2742"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/media\/834"}],"wp:attachment":[{"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/media?parent=833"}],"wp:term":[{"taxonomy":"subsector","embeddable":true,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/subsector?post=833"},{"taxonomy":"stream","embeddable":true,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/stream?post=833"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}