{"id":920,"date":"2026-07-15T09:40:15","date_gmt":"2026-07-15T09:40:15","guid":{"rendered":"https:\/\/altaintegra.com\/insight\/acoustic-design-sound-scoring-foley-stage-studio\/"},"modified":"2026-08-25T13:27:08","modified_gmt":"2026-08-25T13:27:08","slug":"sound-stage-acoustic-design","status":"publish","type":"insight","link":"https:\/\/altaintegra.com\/th\/insight\/sound-stage-acoustic-design\/","title":{"rendered":"Sound Stage Acoustic Design: How Scoring Stages, Foley Rooms and ADR Studios Differ"},"content":{"rendered":"<p class=\"ins-p\">Sound stage acoustic design is a noise-control problem: the target is a very low Noise Criteria rating, as close to silent as construction allows. A scoring stage next door is the opposite: it is designed like a small concert hall, with reverberation as an asset to be tuned rather than a defect to be removed. A Foley room is deliberately dead.<\/p>\n<p class=\"ins-p\">An ADR booth is small, dead-ish, and fighting flutter echo. Four rooms, frequently in the same post-production building, with four incompatible targets.<\/p>\n<p class=\"ins-p\">This article sets out what each room type (sound stage, scoring stage, Foley stage and ADR studio) is actually optimising for, drawn from real production studio references, so that &#8220;studio acoustics&#8221; is not treated as a single specification applied four times.<\/p>\n<div id=\"rank-math-toc\" class=\"wp-block-rank-math-toc-block\">\n<h2>Table of Contents<\/h2>\n<nav>\n<ul>\n<li><a href=\"#four-film-production-room-types-compared\">Four Film-Production Room Types Compared<\/a><\/li>\n<li><a href=\"#sound-stage-acoustic-design-engineering-for-near-silence\">Sound Stage Acoustic Design: Engineering for Near-Silence<\/a><\/li>\n<li><a href=\"#scoring-stage-acoustic-design-a-concert-hall-without-an-audience\">Scoring Stage Acoustic Design: A Concert Hall Without an Audience<\/a><\/li>\n<li><a href=\"#foley-stage-acoustic-design-deliberately-dead\">Foley Stage Acoustic Design: Deliberately Dead<\/a><\/li>\n<li><a href=\"#adr-studio-acoustic-design-small-controlled-not-quite-dead\">ADR Studio Acoustic Design: Small, Controlled, Close to Dead<\/a><\/li>\n<li><a href=\"#why-one-studio-specification-cannot-cover-all-four\">Why One Studio Specification Cannot Cover All Four<\/a><\/li>\n<li><a href=\"#related-work\">Related Sound Stage Insights<\/a><\/li>\n<\/ul>\n<\/nav>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/2026\/07\/01_batam-studio_jpg.webp\" alt=\"Sound stage acoustic design at the I-Studio Batam production facility\" title=\"\"><\/p>\n<h2 class=\"ins-h2\" id=\"four-film-production-room-types-compared\">Four Film-Production Room Types Compared<\/h2>\n<div class=\"ins-table-wrap\">\n<table class=\"ins-table\">\n<thead>\n<tr>\n<th>Room type<\/th>\n<th>Primary acoustic goal<\/th>\n<th>Reverberation<\/th>\n<th>Defining construction measure<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Sound stage<\/td>\n<td>Very low NC rating: near-silence<\/td>\n<td>Controlled, short<\/td>\n<td>Raised floor, structurally isolated walls, independently hung ceiling<\/td>\n<\/tr>\n<tr>\n<td>Scoring stage<\/td>\n<td>Orchestral recording quality<\/td>\n<td>Long and adjustable (Abbey Road Studio One sits at 2.3 s)<\/td>\n<td>Concert-hall-scale volume, diffusive walls and ceiling, variable drapes<\/td>\n<\/tr>\n<tr>\n<td>Foley stage<\/td>\n<td>No room coloration on the recorded effect<\/td>\n<td>Deliberately dead<\/td>\n<td>High-performance absorption over most wall and ceiling area<\/td>\n<\/tr>\n<tr>\n<td>ADR studio<\/td>\n<td>Dialogue matching the original take<\/td>\n<td>Slightly live, close to dead<\/td>\n<td>Thick wall panels, parallel-surface treatment against flutter echo<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"ins-p ins-table-caption\">The sound stage and the scoring stage sit at opposite ends of the same scale. A facility that treats them as one specification ends up with two rooms that each do half a job.<\/p>\n<h2 class=\"ins-h2\" id=\"sound-stage-acoustic-design-engineering-for-near-silence\">Sound Stage Acoustic Design: Engineering for Near-Silence<\/h2>\n<p class=\"ins-p\">A sound stage is a large-format studio for recording moving image and sound indoors. Acoustically, treatment typically covers the full wall and ceiling area with calculated absorptive panels, and floors are finished with 100\u2013150 mm (4\u20136 in) of absorptive carpet material. ALTA Integra&#8217;s portfolio includes a project of this type at I-Studio Batam.<\/p>\n<p class=\"ins-p\">The governing challenge for a sound stage is noise control, and it is a structural problem before it is a finishes problem. Soundproofing has to exclude human activity, transport, rain and mechanical noise.<\/p>\n<p class=\"ins-p\">The standard measures are a raised floor construction isolating the room from ground-transmitted vehicle vibration, structurally isolated walls with vibration dampeners, and a hung ceiling that does not carry vibration or sound from the structure above. Every access point uses a soundproof door.<\/p>\n<p class=\"ins-p\">Cooling is the recurring failure point, because equipment tends to be placed inside or above the room where its noise is hardest to control. The usual answer is to locate cooling plant in a separate room and run distanced diffuser units with an engineered ducting insulation system: structurally isolated ducting, vibration-free suspension, and layered soundproofing around the ducts, so that mechanical vibration does not reach the stage structure. An adjacent control room supports mixing and recording for the sound stage, with microphone signals sent to a wireless receiver typically 23\u201330 m (75\u2013100 ft) away.<\/p>\n<h2 class=\"ins-h2\" id=\"scoring-stage-acoustic-design-a-concert-hall-without-an-audience\">Scoring Stage Acoustic Design: A Concert Hall Without an Audience<\/h2>\n<p class=\"ins-p\">A scoring stage records orchestral music to picture: a conductor works with a full ensemble while a large screen displays the film being scored, musicians monitor through headphones to stay synchronised, and visual cues mark tempo and transitions. The room is large, close to concert hall scale.<\/p>\n<p class=\"ins-p\">Abbey Road&#8217;s Studio One is the reference case. It is the world&#8217;s largest purpose-built recording studio at 4,844 square feet (450 m\u00b2), comfortably hosting a 100-piece orchestra and a 100-piece choir, and it has been the home of London film scoring for over forty years. Its reverberation time is 2.3 seconds, and notably, the room underwent a six-month refurbishment whose explicitly stated priority was <em>not<\/em> changing that figure.<\/p>\n<p class=\"ins-p\">Walls were washed rather than redecorated, the original Art Deco panelling left untouched, the floor re-sanded and oiled but not varnished, and the substantive upgrades confined to the control room. When a room&#8217;s acoustic is the asset, conservation is the design brief.<\/p>\n<p class=\"ins-p\">A scoring stage is built like a concert hall but without seating: flat floors, with irregularly shaped wall and ceiling surfaces to diffuse sound, and reverberation adjustable via curtains or panels. Sessions typically use 5\u20138 microphones for a surround mix, or 30\u201350 when capturing individual instrument groups.<\/p>\n<p class=\"ins-p\">High ceilings make it hard for players to hear each other, so 12\u201318 foldback channels are usually routed from the mixing board back to musicians through headphones to hold timing and balance. Reverberation here is an asset to be tuned, the opposite brief from a sound stage.<\/p>\n<p class=\"ins-p\">One honest limitation: even purpose-built scoring rooms are smaller than a full orchestral concert hall, and the volume available does not always support the reverberation time on offer with a large ensemble in the room. Low-frequency decay in particular can interfere between instrument groups and reduce recording clarity, which is why many classical engineers still prefer concert halls, assembly halls or churches for orchestral work.<\/p>\n<h2 class=\"ins-h2\" id=\"foley-stage-acoustic-design-deliberately-dead\">Foley Stage Acoustic Design: Deliberately Dead<\/h2>\n<p class=\"ins-p\">A Foley stage is where sound effects are performed live to picture (named after Jack Foley, who pioneered the technique). Unlike a sound stage, it is not fighting for near-total silence. It is typically a dead room instead, with most wall and ceiling area covered in high-performance absorbent material, combined with hard surfaces containing small perforations at roughly 3\u20134 square metre intervals.<\/p>\n<p class=\"ins-p\">During a session the Foley artist watches the film on a wall-mounted screen and creates effects live with hands, feet, props and tools: footsteps, a hand slap, water for a shower scene, crockery against cutlery. The room needs clear space around pits built for microphones and props, plus prop storage, typically set into a wall behind an absorbent panel that doubles as a door, with an air gap behind it that helps absorb bass. A separate scratch-track area is part of a well-designed stage.<\/p>\n<p class=\"ins-p\">The atmosphere is kept marginally more live than a standard recording room so the raw effect projects clearly enough into the mix. That is one reason effects work is often done in a conventional recording studio instead, whose acoustic character can suit the job better.<\/p>\n<h2 class=\"ins-h2\" id=\"adr-studio-acoustic-design-small-controlled-not-quite-dead\">ADR Studio Acoustic Design: Small, Controlled, Close to Dead<\/h2>\n<p class=\"ins-p\">Automatic Dialogue Replacement is both a process and a room: dialogue re-recorded after filming, in sync with picture, where the original on-set audio has noise or technical problems that make it unusable. Like the sound stage where the original take was shot, isolation from outside noise still matters here, but the room itself is built on a completely different scale.<\/p>\n<p class=\"ins-p\">An ADR stage is small (sometimes not much larger than a bathroom), and low-frequency decay is the particular concern, so wall panels are commonly at least 50 mm (2 in) thick. Because sessions sometimes include singing, the room is usually designed to retain a small deliberate amount of live character rather than being fully dead, with a typical volume around 2.4 \u00d7 3.7 \u00d7 2.7 m and additional absorbing panels placed around the actor during a session.<\/p>\n<p class=\"ins-p\">Flutter echo (the rapid, buzzy repeat between two parallel hard surfaces) is the key design concern, addressed by treating opposing parallel walls so decay is distributed evenly across the frequency range. Portable panels let the room&#8217;s character be adjusted between sessions.<\/p>\n<h2 class=\"ins-h2\" id=\"why-one-studio-specification-cannot-cover-all-four\">Why One Studio Specification Cannot Cover All Four<\/h2>\n<p class=\"ins-p\">Across all four room types the discipline is the same even though the targets are opposite: match noise control, reverberation and diffusion to the specific task the room performs, rather than applying a generic &#8220;studio acoustics&#8221; package. Many post-production facilities house all four (sound stage, scoring stage, Foley stage and ADR studio) in one building, and each still needs its own design. This is the approach ALTA Integra takes to media-production facilities through its <a href=\"\/services\/acoustic-consultant\/\">acoustic engineering and design<\/a> practice.<\/p>\n<h2 class=\"ins-h2\" id=\"faq\">FAQ<\/h2>\n<div class=\"ins-faq\">\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>What is the main acoustic design goal of a sound stage?<\/strong><\/p>\n<p class=\"ins-faq-a\">Achieving a very low Noise Criteria rating: keeping the room as free of external and mechanical noise as construction allows. That means soundproof construction, a raised floor isolating the room from ground-borne vehicle vibration, an independently hung ceiling, and cooling plant relocated outside the room with isolated ducting.<\/p>\n<\/div>\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>How is a scoring stage different from a sound stage?<\/strong><\/p>\n<p class=\"ins-faq-a\">A scoring stage is built like a small concert hall: diffusive wall and ceiling surfaces, concert-hall-scale volume, and a reverberation time tuned for orchestral recording and adjustable with drapes. A sound stage does the opposite, prioritising isolation and near-silence for filming. They are opposite targets in the same building.<\/p>\n<\/div>\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>What is the reverberation time of Abbey Road Studio One?<\/strong><\/p>\n<p class=\"ins-faq-a\">2.3 seconds, unchanged since the 1970s. The 4,844-square-foot room is the world&#8217;s largest purpose-built recording studio and hosts a 100-piece orchestra. A recent six-month refurbishment was carried out specifically to preserve that acoustic: walls washed rather than redecorated, upgrades confined largely to the control room.<\/p>\n<\/div>\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>Why is a Foley stage designed to be acoustically dead?<\/strong><\/p>\n<p class=\"ins-faq-a\">Foley work adds live-performed effects to picture, so the room needs high absorption and minimal reflection to keep its own coloration out of the recorded effect. Most wall and ceiling area is covered in high-performance absorbent material, with hard perforated surfaces distributed through it.<\/p>\n<\/div>\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>Why does an ADR studio need to be small and tightly controlled?<\/strong><\/p>\n<p class=\"ins-faq-a\">ADR re-records dialogue after filming, so the result has to sit convincingly against the original take. The room is kept small and treated for low-frequency decay and flutter echo, with wall panels at least 50 mm thick and opposing parallel surfaces treated so reverberation is even across the frequency range.<\/p>\n<\/div>\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>Who designs post-production studio acoustics in Indonesia?<\/strong><\/p>\n<p class=\"ins-faq-a\">ALTA Integra designs sound stages, scoring stages, Foley rooms and ADR studios for media-production facilities across Indonesia and Southeast Asia, including the I-Studio Batam sound stage, matching noise control and reverberation targets to each room&#8217;s specific function.<\/p>\n<\/div>\n<\/div>\n<h2 class=\"ins-h2\" id=\"sources\">Sources<\/h2>\n<p class=\"ins-p\">1. <a href=\"https:\/\/www.abbeyroad.com\/studio-one\" target=\"_blank\" rel=\"noopener\">Abbey Road Studios, &#8220;Studio One&#8221;<\/a> : 4,844 sq ft, 100-piece orchestra and choir capacity.<br \/>\n2. Associated Press, &#8220;The delicate dance to preserve the magic of Abbey Road&#8217;s legendary Studio One,&#8221; April 2025: reverberation maintained at 2.3 seconds through refurbishment.<br \/>\n3. <a href=\"https:\/\/acousticstoday.org\/wp-content\/uploads\/2017\/10\/Article_3of4_from_ATCODK_9_2.pdf\" target=\"_blank\" rel=\"noopener\">Acoustics Today, &#8220;The Motion Picture Scoring Stage,&#8221;<\/a> April 2013.<br \/>\n4. ANSI\/ASA S12.2-2019 (R2023), Criteria for Evaluating Room Noise.<\/p>\n<p><!--alta-seo-block--><\/p>\n<h2 id=\"related-work\" class=\"ins-h2\">Related Sound Stage Insights and Project Work<\/h2>\n<p class=\"ins-p\">Further Sound Stage material from ALTA Integra: related technical insights, and the built projects where this engineering was applied.<\/p>\n<ul class=\"ins-related\">\n<li><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/2026\/07\/01_conferoom-1_jpg.webp\" alt=\"Acoustic Design for Meeting Rooms, Offices and Classrooms: RT60 Targets by Room Type : related sound stage work by ALTA Integra\" loading=\"lazy\" title=\"\"> <strong>Insight:<\/strong> <a href=\"https:\/\/altaintegra.com\/insight\/rt60-targets-by-room-type\/\">Acoustic Design for Meeting Rooms, Offices and Classrooms: RT60 Targets by Room Type<\/a> . Every room where an audience listens has a reverberation time it should hit, and the world&#8217;s most famous concert hall spent fifty years proving what happens when it doesn&#8217;t.<\/li>\n<li><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/2026\/07\/01_gambar_2_jpg.webp\" alt=\"Music Studio Acoustic Design: Isolation, Treatment and RT60 Targets for Home and Commercial Rooms : related sound stage work by ALTA Integra\" loading=\"lazy\" title=\"\"> <strong>Insight:<\/strong> <a href=\"https:\/\/altaintegra.com\/insight\/music-studio-acoustic-design\/\">Music Studio Acoustic Design: Isolation, Treatment and RT60 Targets for Home and Commercial Rooms<\/a> . Two problems that get confused constantly: keeping sound out of the room, and controlling what the room does to the sound already inside it.<\/li>\n<li><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/2026\/07\/01_Ruang-Take-1_jpg.webp\" alt=\"Professional Recording Studio Design: The Room Programme and Why Room Ratio Comes First : related sound stage work by ALTA Integra\" loading=\"lazy\" title=\"\"> <strong>Insight:<\/strong> <a href=\"https:\/\/altaintegra.com\/insight\/room-ratio-recording-studio-design\/\">Professional Recording Studio Design: The Room Programme and Why Room Ratio Comes First<\/a> . A commercial studio, rather than one room with treatment on the walls, is four or five rooms with incompatible acoustic targets, sharing a building.<\/li>\n<li><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/inifinite-batam.jpg\" alt=\"Infinite Movie Studio Batam : related sound stage work by ALTA Integra\" loading=\"lazy\" title=\"\"> <strong>Project:<\/strong> <a href=\"https:\/\/altaintegra.com\/project\/infinite-batam\/\">Infinite Movie Studio Batam<\/a> . Flexible acoustic envelopes for movie, music, foley, and dubbing: same studio, different days, same neutral reference.<\/li>\n<li><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/md-picture.jpg\" alt=\"MD Pictures Jakarta : related sound stage work by ALTA Integra\" loading=\"lazy\" title=\"\"> <strong>Project:<\/strong> <a href=\"https:\/\/altaintegra.com\/project\/md-pictures\/\">MD Pictures Jakarta<\/a> . Total design for a national film studio: tracking, dubbing, foley, and post all from one acoustic master plan.<\/li>\n<\/ul>\n<p><!--\/alta-seo-block--><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Sound stage acoustic design is a noise-control problem: [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":921,"template":"","meta":{"_acf_changed":false,"footnotes":""},"subsector":[],"stream":[4],"class_list":["post-920","insight","type-insight","status-publish","has-post-thumbnail","hentry","stream-perspective"],"acf":[],"_links":{"self":[{"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/insights\/920","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/insights"}],"about":[{"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/types\/insight"}],"version-history":[{"count":5,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/insights\/920\/revisions"}],"predecessor-version":[{"id":2226,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/insights\/920\/revisions\/2226"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/media\/921"}],"wp:attachment":[{"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/media?parent=920"}],"wp:term":[{"taxonomy":"subsector","embeddable":true,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/subsector?post=920"},{"taxonomy":"stream","embeddable":true,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/stream?post=920"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}