{"id":1990,"date":"2026-08-10T05:55:06","date_gmt":"2026-08-10T05:55:06","guid":{"rendered":"https:\/\/altaintegra.com\/resources\/standards\/"},"modified":"2026-08-24T17:06:01","modified_gmt":"2026-08-24T17:06:01","slug":"standards","status":"publish","type":"page","link":"https:\/\/altaintegra.com\/th\/resources\/standards\/","title":{"rendered":"Standards &#038; Regulations"},"content":{"rendered":"<div id=\"rank-math-toc\" class=\"wp-block-rank-math-toc-block\">\n<h2>Table of Contents<\/h2>\n<nav>\n<ul>\n<li><a href=\"#overview\">Standards<\/a><\/li>\n<li><a href=\"#acoustic-standards\">Acoustic Standards<\/a><\/li>\n<li><a href=\"#indonesian-standards\">Indonesian Standards and Regulations<\/a><\/li>\n<li><a href=\"#lighting-standards\">Lighting Standards<\/a><\/li>\n<li><a href=\"#audiovisual-standards\">Audiovisual and ICT Standards<\/a><\/li>\n<li><a href=\"#envelope-standards\">Building Envelope and Energy Standards<\/a><\/li>\n<li><a href=\"#certification-standards\">Green and Healthy Building Certification<\/a><\/li>\n<li><a href=\"#how-we-apply-them\">How We Apply These Standards<\/a><\/li>\n<li><a href=\"#related-work\">Related Work<\/a><\/li>\n<\/ul>\n<\/nav>\n<\/div>\n<h2 id=\"overview\">Standards<\/h2>\n<p>These are the standards every ALTA Integra design is measured against, listed openly so any number we give you can be checked.<\/p>\n<p>Fifty standards and regulations across five disciplines. Indonesian requirements set the compliance baseline on an Indonesian project; international standards are used alongside them as the higher design target, or where a project needs a metric that Indonesian standards do not define. Edition years are shown only where the current edition was verified against the issuing body, because a stale year on a consultant&#8217;s standards page is worse than no year at all.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/01_pengukuran-akustik2_jpg.webp\" alt=\"On-site verification against the acoustic standards ALTA Integra designs to\" style=\"max-width:100%\" title=\"\"><\/p>\n<h2 id=\"acoustic-standards\">Acoustic Standards<\/h2>\n<p>Room acoustics follow the <a href=\"https:\/\/www.iso.org\/standard\/77437.html\" target=\"_blank\" rel=\"noopener\">ISO 3382 series<\/a>, Part 1 for performance spaces, Part 2 for reverberation time in ordinary rooms, Part 3 for open-plan offices, where spatial decay of speech and distraction distance are the meaningful measures rather than reverberation time alone. Sound insulation is rated by ISO 717-1 and ISO 717-2 and verified in the field to ISO 16283, with the prediction model in ISO 12354 behind our design-stage numbers, including flanking transmission.<\/p>\n<p>The equivalent North American acoustic standards are carried alongside because most partition and door datasheets on the Indonesian market quote them: ASTM E90 for laboratory transmission loss, ASTM E413 for the STC classification derived from it, ASTM C423 for absorption coefficients, and ASTM E336 and E1007 for field ratings. Speech intelligibility follows IEC 60268-16:2020, and every sound level meter conforms to IEC 61672 Class 1.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/01_music-hall2_jpg.webp\" alt=\"Concert hall interior designed against the ISO room acoustic standards listed here\" style=\"max-width:100%\" title=\"\"><\/p>\n<h2 id=\"indonesian-standards\">Indonesian Standards and Regulations<\/h2>\n<p>Environmental noise in Indonesia is measured under SNI 8427:2017, which samples LAeq for ten minutes in each hour across a full twenty-four hours and reduces the result to daytime, night-time and combined levels. Those are compared against the statutory limits per land-use zone in KepMenLH 48\/1996. Room criteria come from SNI 03-6386-2000, and occupational noise exposure from Permenaker 5\/2018. These are the standards a project is actually assessed against by an Indonesian authority.<\/p>\n<h2 id=\"lighting-standards\">Lighting Standards<\/h2>\n<p>Indonesian lighting work is governed by SNI 6197:2020 for lighting power density, SNI 03-6575-2001 for artificial lighting design and SNI 03-2396-2001 for daylight. EN 12464-1:2021 supplies the workplace criteria most international specifications cite: maintained illuminance, uniformity, the UGR glare limits defined in CIE 117, and colour rendering by activity. Product data is accepted only from an IES LM-79 test, with LM-80 and TM-21 behind any lumen-maintenance claim and TM-30 where colour fidelity genuinely sells something.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/01_light_pollution_jpg.webp\" alt=\"Exterior lighting assessed against the outdoor lighting standards in this list\" style=\"max-width:100%\" title=\"\"><\/p>\n<h2 id=\"audiovisual-standards\">Audiovisual and ICT Standards<\/h2>\n<p>Audiovisual work follows the <a href=\"https:\/\/www.avixa.org\/standards\/current-standards\" target=\"_blank\" rel=\"noopener\">ANSI\/AVIXA series<\/a>: A102.01:2022 for audio coverage uniformity, A103.01:2023 for spectral balance, V202.01:2026 (DISCAS) for display image size, V201.01:2021 (ISCR) for contrast measured with real ambient light present, D401.01:2023 for documentation and D402.02:2013 (R2024) for performance verification at handover. Cabling and containment follow ISO\/IEC 11801 and the ANSI\/TIA-568 and 569 series.<\/p>\n<h2 id=\"envelope-standards\">Building Envelope and Energy Standards<\/h2>\n<p>Envelope performance is assessed by OTTV and RTTV under SNI 6389:2020, with a 35 W\/m\u00b2 OTTV ceiling as the usual compliance target, alongside ASHRAE 90.1 for the energy budget, ASHRAE 55 for thermal comfort and ASHRAE 62.1 for ventilation, the last of which is also an acoustic constraint, since more air usually means more duct noise. National green building performance is assessed under Permen PUPR 21\/2021, which awards Pratama, Madya or Utama ratings.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/01_kenyamanan-thermal04_jpg.webp\" alt=\"Facade shading study assessed against the building envelope standards listed here\" style=\"max-width:100%\" title=\"\"><\/p>\n<h2 id=\"certification-standards\">Green and Healthy Building Certification<\/h2>\n<p>We prepare documentation and simulations for GREENSHIP from the Green Building Council Indonesia, for LEED v5, and for <a href=\"https:\/\/www.wellcertified.com\/well\/\" target=\"_blank\" rel=\"noopener\">WELL v2<\/a>, whose Sound and Light concepts are where our acoustic and lighting scope earns certification points directly. See <a href=\"https:\/\/altaintegra.com\/services\/green-building-certification\/\">green building certification<\/a> and <a href=\"https:\/\/altaintegra.com\/services\/health-building-certification\/\">health building certification<\/a>.<\/p>\n<h2 id=\"how-we-apply-them\">How We Apply These Standards<\/h2>\n<p>A published requirement is a floor, not a design. We set the criterion for each space, predict against it at design stage, and verify it by measurement on the finished building. Where an Indonesian and an international requirement disagree, the Indonesian one is the compliance baseline and the international one is treated as the higher design target: a distinction worth writing into a brief early, because it changes what a contractor is obliged to deliver.<\/p>\n<p>Compliance and comfort are also not the same thing, and conflating them is a frequent source of disappointment. A meeting room can satisfy every applicable requirement and still be unpleasant to sit in, because the criteria are minima written to protect against clear failure rather than recipes for a good room. Reverberation within range says nothing about whether early reflections arrive usefully; illuminance on target says nothing about whether the space feels flat. We treat the published figure as the point below which a design is indefensible, and the brief as the thing that decides how far above it to aim.<\/p>\n<p>Editions change, too. A specification written against a superseded document can require something the current one no longer asks for, or omit something it now does, which is why the reference list on this page is dated and why we re-check it rather than carrying an old project&#8217;s front matter forward. Where a client&#8217;s own corporate guideline conflicts with a national requirement, both are recorded and the stricter governs.<\/p>\n<h2 id=\"reading-a-specification\">Reading a Specification<\/h2>\n<p>Three things are worth checking in any specification that cites a document number. First, whether the cited figure is a laboratory rating or a field rating: the two are not interchangeable, and a contractor can install a compliant product and still miss a field target. Second, whether a single-number rating carries the adaptation term appropriate to the actual noise, a partition perfectly adequate against office chatter can be transparent to a nightclub next door. Third, whether the criterion is stated as a design target or an acceptance criterion, because only the second is testable at handover.<\/p>\n<h2 id=\"related-work\">Related Work<\/h2>\n<p>The <a href=\"https:\/\/altaintegra.com\/resources\/terminology\/\">terminology<\/a> section defines every quantity named above, the <a href=\"https:\/\/altaintegra.com\/resources\/calculator\/\">calculators<\/a> implement several of these methods, the <a href=\"https:\/\/altaintegra.com\/resources\/tools\/\">tools<\/a> page lists what we verify them with, and the <a href=\"https:\/\/altaintegra.com\/resources\/faq\/\">FAQ<\/a> covers how the two systems are reconciled in practice. <a href=\"https:\/\/altaintegra.com\/contact\/\">Contact us<\/a> to discuss the criteria for a specific project.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Table of Contents Standards Acoustic Standards Indonesi [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":0,"parent":1738,"menu_order":30,"comment_status":"closed","ping_status":"closed","template":"page-standards.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-1990","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/pages\/1990","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/comments?post=1990"}],"version-history":[{"count":2,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/pages\/1990\/revisions"}],"predecessor-version":[{"id":2154,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/pages\/1990\/revisions\/2154"}],"up":[{"embeddable":true,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/pages\/1738"}],"wp:attachment":[{"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/media?parent=1990"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}