{"id":1991,"date":"2026-08-10T05:55:07","date_gmt":"2026-08-10T05:55:07","guid":{"rendered":"https:\/\/altaintegra.com\/resources\/terminology\/"},"modified":"2026-08-24T17:05:59","modified_gmt":"2026-08-24T17:05:59","slug":"terminology","status":"publish","type":"page","link":"https:\/\/altaintegra.com\/th\/resources\/terminology\/","title":{"rendered":"Terms &#038; Definitions"},"content":{"rendered":"<div id=\"rank-math-toc\" class=\"wp-block-rank-math-toc-block\">\n<h2>Table of Contents<\/h2>\n<nav>\n<ul>\n<li><a href=\"#overview\">Terminology<\/a><\/li>\n<li><a href=\"#acoustic-terminology\">Acoustic Terminology<\/a><\/li>\n<li><a href=\"#insulation-terminology\">Sound Insulation Terminology<\/a><\/li>\n<li><a href=\"#lighting-terminology\">Lighting Terminology<\/a><\/li>\n<li><a href=\"#audiovisual-terminology\">Audiovisual Terminology<\/a><\/li>\n<li><a href=\"#envelope-terminology\">Envelope Terminology<\/a><\/li>\n<li><a href=\"#using-this-glossary\">Using This Glossary<\/a><\/li>\n<li><a href=\"#related-work\">Related Work<\/a><\/li>\n<\/ul>\n<\/nav>\n<\/div>\n<h2 id=\"overview\">Terminology<\/h2>\n<p>This terminology glossary explains, in plain language, every technical term that appears in an ALTA Integra report.<\/p>\n<p>Thirty-four definitions across acoustics, lighting, audiovisual and building envelope, searchable and filterable by discipline. It is written for the architect, project manager or building owner reading an engineering report, not for engineers who already know it. Where a term has both an ISO and an ASTM equivalent, both are given, because specifications in Indonesia routinely mix the two in a single document and the numbers are not interchangeable.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/lighting-measurement-1.webp\" alt=\"Field measurement producing the quantities defined in this acoustic and lighting terminology glossary\" style=\"max-width:100%\" title=\"\"><\/p>\n<h2 id=\"acoustic-terminology\">Acoustic Terminology<\/h2>\n<p>The room-acoustic terminology covers reverberation time and the Sabine and Eyring equations behind it; absorption coefficient with its NRC and \u03b1w single-number summaries; the NC and NR background-noise curves that describe how quiet a room has to be; LAeq, the energy-equivalent level underlying almost every environmental noise limit; room modes and the Schroeder frequency that marks where they stop dominating; and the Speech Transmission Index, which quantifies whether speech is understood rather than merely heard.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/02_room-modes1_jpg.webp\" alt=\"Room mode pressure distribution illustrating one entry in this acoustic terminology glossary\" style=\"max-width:100%\" title=\"\"><\/p>\n<h2 id=\"insulation-terminology\">Sound Insulation Terminology<\/h2>\n<p>The insulation terminology is where most specification errors originate, so it is covered carefully: STC and its ISO counterparts Rw and DnT,w; the C and Ctr spectrum adaptation terms that correct a rating for the noise actually being blocked; the impact ratings Ln,w and IIC, which run in opposite directions, lower is better for one, higher for the other; and flanking transmission, the reason a wall tested at Rw 55 in a laboratory can deliver DnT,w 42 on site.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/01_bedroom-and-concert-hall-min-1024x545-1_png.webp\" alt=\"Two rooms with very different insulation requirements, as described in this terminology glossary\" style=\"max-width:100%\" title=\"\"><\/p>\n<h2 id=\"lighting-terminology\">Lighting Terminology<\/h2>\n<p>The lighting terminology covers illuminance and luminance, and why glare is a luminance problem rather than an illuminance one; maintained illuminance and the maintenance factor, whose omission is the most common cause of a compliant scheme failing two years later; Unified Glare Rating; uniformity; colour rendering and colour temperature including the Rf and Rg measures from TM-30; lighting power density; the lumen and point-by-point methods; room index; utilisation factor; the IES photometric data file; and daylight factor.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/01_light_pollution_jpg.webp\" alt=\"Exterior lighting demonstrating several quantities defined in this lighting terminology section\" style=\"max-width:100%\" title=\"\"><\/p>\n<h2 id=\"audiovisual-terminology\">Audiovisual Terminology<\/h2>\n<p>The audiovisual terminology covers potential and needed acoustic gain, the feedback-stability check for any live sound system; DISCAS display image sizing; and Image System Contrast Ratio, the metric that exposes a bright meeting room specified with a projector that cannot win against it.<\/p>\n<h2 id=\"envelope-terminology\">Envelope Terminology<\/h2>\n<p>The envelope group covers OTTV and RTTV, window-to-wall ratio, solar heat gain coefficient, and thermal transmittance or U-value, the four quantities that decide whether a facade concept will pass or need reworking.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/01_green-building_jpg.webp\" alt=\"Building facade illustrating the envelope terminology defined in this glossary\" style=\"max-width:100%\" title=\"\"><\/p>\n<h2 id=\"pairs-that-get-confused\">Pairs That Get Confused<\/h2>\n<p>A handful of pairs account for most of the misunderstandings we see in briefs and tenders, so the glossary treats each pair together rather than alphabetically apart. Illuminance and luminance are the first: one is light arriving on a surface and is what a meter reads, the other is light leaving it toward the eye and is what a person perceives as brightness. Specifying the first and hoping for the second is how a corridor ends up technically bright and visually grim.<\/p>\n<p>Absorption and insulation are the second pair, and the most expensive to confuse. Soft finishes reduce reflected sound within a room; they do almost nothing to stop sound passing through the wall. A client who asks for panels because a neighbour can be heard has usually been sold the wrong product by someone happy to supply it.<\/p>\n<p>Laboratory and field ratings are the third. A number measured in a controlled chamber describes an element in isolation, with no flanking path, no penetration and no workmanship variation. The field equivalent describes the building that was actually built. They are related but never equal, and a specification that quotes one while testing for the other guarantees an argument at handover.<\/p>\n<p>Average and minimum are the fourth. An average illuminance, an average reverberation time or an average sound level can all sit comfortably on target while a substantial part of the space fails badly, which is why uniformity and spatial distribution appear alongside every average in a well-written criterion.<\/p>\n<h2 id=\"using-this-glossary\">Using This Glossary<\/h2>\n<p>Each entry gives the symbol or abbreviation exactly as it appears in a report, then what the quantity means and why it matters in practice. The <a href=\"https:\/\/altaintegra.com\/resources\/standards\/\">standards<\/a> section names the document each is defined in, and the <a href=\"https:\/\/altaintegra.com\/resources\/calculator\/\">calculators<\/a> let you compute several of them directly. Definitions here follow the published documents; where a word is used loosely in the market, the entry says so. Further background is published by bodies such as <a href=\"https:\/\/acousticalsociety.org\/\" target=\"_blank\" rel=\"noopener\">the Acoustical Society of America<\/a>.<\/p>\n<h2 id=\"related-work\">Related Work<\/h2>\n<p>The <a href=\"https:\/\/altaintegra.com\/resources\/faq\/\">FAQ<\/a> covers the questions this terminology usually prompts, and the <a href=\"https:\/\/altaintegra.com\/resources\/tools\/\">tools<\/a> page lists the instruments that measure these quantities. For anything unclear in a report we have issued, <a href=\"https:\/\/altaintegra.com\/contact\/\">ask us directly<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Table of Contents Terminology Acoustic Terminology Soun [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":0,"parent":1738,"menu_order":40,"comment_status":"closed","ping_status":"closed","template":"page-terminology.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-1991","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/pages\/1991","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/comments?post=1991"}],"version-history":[{"count":2,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/pages\/1991\/revisions"}],"predecessor-version":[{"id":2152,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/pages\/1991\/revisions\/2152"}],"up":[{"embeddable":true,"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/pages\/1738"}],"wp:attachment":[{"href":"https:\/\/altaintegra.com\/th\/wp-json\/wp\/v2\/media?parent=1991"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}