{"id":950,"date":"2026-07-15T09:40:16","date_gmt":"2026-07-15T09:40:16","guid":{"rendered":"https:\/\/altaintegra.com\/insight\/jakarta-air-quality-emergency\/"},"modified":"2026-08-25T13:27:25","modified_gmt":"2026-08-25T13:27:25","slug":"indoor-air-quality-jakarta-leed-well","status":"publish","type":"insight","link":"https:\/\/altaintegra.com\/zh\/insight\/indoor-air-quality-jakarta-leed-well\/","title":{"rendered":"Indoor Air Quality in Jakarta Buildings: What LEED v5 and WELL v2 Require"},"content":{"rendered":"<p class=\"ins-p\">Jakarta&#8217;s annual average PM2.5 concentration was 41.7 \u00b5g\/m&sup3; in 2024, or 8.3 times the World Health Organization&#8217;s annual guideline of 5 \u00b5g\/m&sup3;. That pollution does not stop at the building envelope. Research across industrialized Asian countries has found indoor PM2.5 concentrations that exceed outdoor levels, driven by limited ventilation, envelope infiltration, and inadequate filtration: a combination that steadily degrades indoor air quality regardless of outdoor conditions.<\/p>\n<p class=\"ins-p\">For building owners in Jakarta, this makes indoor air quality a design and operations problem to manage directly. Both LEED and WELL treat it as a certification criterion: LEED v5, released in April 2025, and WELL v2 both build indoor air quality into their core requirements, and LEED v4.1 registration remains open through June 30, 2027 for owners already on that path.<\/p>\n<p class=\"ins-p\">ALTA Integra advises building owners in Jakarta and across Indonesia on the building physics behind those requirements. This article covers where Jakarta&#8217;s pollution originates, why indoor air quality can be worse than outdoor air quality, and what filtration and design measures measurably reduce occupant exposure.<\/p>\n<div id=\"rank-math-toc\" class=\"wp-block-rank-math-toc-block\">\n<h2>Table of Contents<\/h2>\n<nav>\n<ul>\n<li><a href=\"#who-2021-air-quality-guidelines-vs-jakarta\">WHO 2021 Air Quality Guidelines vs. Jakarta<\/a><\/li>\n<li><a href=\"#why-indoor-air-quality-is-a-building-design-issue-not-just-an-outdoor-one\">Why Indoor Air Quality Is Primarily a Building Design and Operations Issue<\/a><\/li>\n<li><a href=\"#where-jakartas-air-pollution-comes-from\">Where Jakarta&#x27;s Air Pollution Comes From<\/a><\/li>\n<li><a href=\"#why-indoor-air-quality-can-be-worse-than-outdoor-air\">Why Indoor Air Quality Can Be Worse Than Outdoor Air<\/a><\/li>\n<li><a href=\"#how-to-reduce-indoor-pm25-in-jakarta-office-buildings\">How to Reduce Indoor PM2.5 in Jakarta Office Buildings<\/a><\/li>\n<li><a href=\"#faq\">FAQ<\/a><\/li>\n<li><a href=\"#related-work\">Related Indoor Air Quality Insights<\/a><\/li>\n<\/ul>\n<\/nav>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/2026\/07\/01_p_15359809782d6-jakarta-darurat-polusi-udara_jpg.webp\" alt=\"Indoor air quality haze over Jakarta high-rise buildings\" title=\"\"><\/p>\n<h2 class=\"ins-h2\" id=\"who-2021-air-quality-guidelines-vs-jakarta\">WHO 2021 Air Quality Guidelines vs. Jakarta<\/h2>\n<p class=\"ins-p\">The World Health Organization revised its air quality guidelines in September 2021, tightening most limits significantly from the 2005 version: the annual PM2.5 guideline was halved, from 10 to 5 \u00b5g\/m&sup3;. Because outdoor concentrations set the baseline for infiltration, this tightening directly raises the bar for indoor air quality inside naturally ventilated buildings.<\/p>\n<div class=\"ins-table-wrap\">\n<table class=\"ins-table\">\n<thead>\n<tr>\n<th>Pollutant<\/th>\n<th>WHO 2021 annual limit<\/th>\n<th>WHO 2021 24-hour limit<\/th>\n<th>Previous 2005 limit (annual)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>PM2.5<\/td>\n<td>5 \u00b5g\/m&sup3;<\/td>\n<td>15 \u00b5g\/m&sup3;<\/td>\n<td>10 \u00b5g\/m&sup3;<\/td>\n<\/tr>\n<tr>\n<td>PM10<\/td>\n<td>15 \u00b5g\/m&sup3;<\/td>\n<td>45 \u00b5g\/m&sup3;<\/td>\n<td>20 \u00b5g\/m&sup3;<\/td>\n<\/tr>\n<tr>\n<td>NO2<\/td>\n<td>10 \u00b5g\/m&sup3;<\/td>\n<td>25 \u00b5g\/m&sup3;<\/td>\n<td>40 \u00b5g\/m&sup3;<\/td>\n<\/tr>\n<tr>\n<td>O3<\/td>\n<td>60 \u00b5g\/m&sup3; (peak season)<\/td>\n<td>100 \u00b5g\/m&sup3; (8-hour)<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"ins-p ins-table-caption\">Jakarta&#8217;s 2024 annual PM2.5 average was 41.7 \u00b5g\/m&sup3;, or 8.3&times; the current WHO guideline.<\/p>\n<h2 class=\"ins-h2\" id=\"why-indoor-air-quality-is-a-building-design-issue-not-just-an-outdoor-one\">Why Indoor Air Quality Is Primarily a Building Design and Operations Issue<\/h2>\n<p class=\"ins-p\">The Special Capital Region of Jakarta (Jakarta Raya) is the most polluted province in Indonesia: the average resident there could live 2.6 years longer if particulate concentrations met the WHO guideline, according to the University of Chicago&#8217;s Air Quality Life Index (AQLI), based on 2023 PM2.5 data. That outdoor pollution burden is exactly why indoor air quality has become a core criterion in green building certifications such as <a href=\"\/services\/green-building-certification\/\">LEED and WELL<\/a>: the WHO&#8217;s threshold values are commonly measured across four pollutants, namely particulate matter (PM), ozone (O3), nitrogen dioxide (NO2), and sulfur dioxide (SO2). Buildings sit directly in that exposure pathway.<\/p>\n<p class=\"ins-p\">Public awareness of air quality in Indonesia has been rising alongside growing recognition that clean, safe air is a basic human right. Jakarta&#8217;s air quality index has historically exceeded WHO exposure limits often enough that the city&#8217;s air is classified as unhealthy for extended periods of the year.<\/p>\n<h2 class=\"ins-h2\" id=\"where-jakartas-air-pollution-comes-from\">Where Jakarta&#8217;s Air Pollution Comes From<\/h2>\n<p class=\"ins-p\">Motor vehicle exhaust is the dominant source of Jakarta&#8217;s air pollution. A study by Bandung Institute of Technology (ITB), funded by the Toyota Clean Air Project, measured PM2.5 at Gelora Bung Karno, Kebon Jeruk, and Lubang Buaya across the 2018&ndash;2019 rainy and dry seasons.<\/p>\n<p class=\"ins-p\">After vehicle exhaust, the largest contributors were asphalt road dust, open burning, construction activity, sea salt, soil, and coal combustion. Sea salt, carried inland by onshore sea breezes, was the leading non-vehicle source at all three sites.<\/p>\n<p class=\"ins-p\">The study also found a clear seasonal pattern: rainy-season concentrations ran consistently below dry-season levels, because rainfall precipitates airborne particles and carries them into drainage, a process called wet deposition. Because mechanical ventilation draws directly from this same outdoor air, every source above becomes a direct input to indoor air quality inside Jakarta buildings.<\/p>\n<h2 class=\"ins-h2\" id=\"why-indoor-air-quality-can-be-worse-than-outdoor-air\">Why Indoor Air Quality Can Be Worse Than Outdoor Air<\/h2>\n<p class=\"ins-p\">Indoor air quality can be worse than outdoor air quality: indoor PM2.5 concentrations can exceed outdoor levels, according to research by Jones et al. in China and India, both, like Indonesia, industrialized Asian countries, found exactly this. Three factors drive it: a lack of ventilation openings during working hours, outdoor PM2.5 infiltrating through the building envelope, and higher ventilation exchange rates without adequate filtration. Many building ventilation systems also maintain positive pressure during peak hours to reduce cooling load, which lowers fresh-air exchange and lets indoor PM2.5 accumulate.<\/p>\n<p class=\"ins-p\">A study by Pramitha and Haryanto on indoor PM2.5 exposure and lung function in Jakarta&#8217;s Pulo Gadung industrial area found that when occupants inhale PM2.5-laden air that reaches the alveoli, the resulting interaction between particles and oxygen metabolites can overwhelm the body&#8217;s ability to neutralize free radicals. This produces oxidative stress that inflames the lungs and limits lung expansion. Long-term exposure is linked to reduced indoor lung function, one clinical reason poor indoor air quality is treated as a health issue.<\/p>\n<h2 class=\"ins-h2\" id=\"how-to-reduce-indoor-pm25-in-jakarta-office-buildings\">How to Reduce Indoor PM2.5 in Jakarta Office Buildings<\/h2>\n<p class=\"ins-p\">Filtering ventilation air through a MERV 13-rated filter or better measurably reduces indoor PM2.5 concentration, according to research by Jones et al. across office buildings in four countries, and is one of the most effective single interventions for improving indoor air quality. Supplementary air purifiers positioned near a pollution source, operated in a mode that directs clean air to the breathing zone, add further reduction.<\/p>\n<p class=\"ins-p\">At the building level, <a href=\"\/services\/green-building-certification\/\">LEED Operations and Maintenance (O+M)<\/a> and the <a href=\"\/services\/health-building-certification\/\">WELL Building Standard<\/a> both give owners a structured way to verify and improve indoor air quality: LEED with a focus on sustainable, efficient buildings, and WELL with a focus on occupant well-being, comfort, and health. Good indoor air quality supports human productivity, health, and welfare, and helps fulfill the basic right to a healthier living environment. Integrating building architecture with building physics is what makes that possible in practice, which is the core of what ALTA Integra does for clients pursuing LEED and WELL certification for buildings in Jakarta and beyond.<\/p>\n<h2 class=\"ins-h2\" id=\"faq\">FAQ<\/h2>\n<div class=\"ins-faq\">\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>How bad is Jakarta&#8217;s air quality?<\/strong><\/p>\n<p class=\"ins-faq-a\">Jakarta&#8217;s annual average PM2.5 concentration reached 41.7 \u00b5g\/m&sup3; in 2024, or 8.3 times the World Health Organization&#8217;s annual guideline of 5 \u00b5g\/m&sup3;. The WHO tightened that guideline in September 2021, halving it from the previous 10 \u00b5g\/m&sup3;. Indoor concentrations inside Jakarta buildings can be higher still, because outdoor particulate infiltrates the building envelope and accumulates where ventilation and filtration are inadequate.<\/p>\n<\/div>\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>What is the main source of Jakarta&#8217;s air pollution?<\/strong><\/p>\n<p class=\"ins-faq-a\">Motor vehicle exhaust is the dominant source. A Bandung Institute of Technology study funded by the Toyota Clean Air Project measured PM2.5 at three Jakarta sites and identified vehicle emissions as the largest contributor, followed by asphalt road dust, open burning, construction activity, sea salt, soil, and coal combustion. Sea salt, carried by onshore breezes, was the leading non-vehicle source at every site.<\/p>\n<\/div>\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>Can indoor air be more polluted than outdoor air?<\/strong><\/p>\n<p class=\"ins-faq-a\">Yes. Research by Jones et al. across office buildings in four countries found indoor PM2.5 concentrations that exceeded outdoor levels. Three factors drive this: ventilation openings kept closed during working hours, outdoor particulate infiltrating through the building envelope, and ventilation systems held at positive pressure to reduce cooling load, which lowers fresh-air exchange and lets particulate accumulate indoors.<\/p>\n<\/div>\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>What MERV rating is needed to reduce indoor PM2.5?<\/strong><\/p>\n<p class=\"ins-faq-a\">A minimum MERV 13 rating. Research by Jones et al. found that filtering ventilation air at MERV 13 or above measurably reduces indoor PM2.5 concentration in office buildings. Lower ratings such as MERV 8 capture coarser particles but pass a substantial fraction of PM2.5. Portable air purifiers near identified pollution sources provide additional reduction where central filtration alone is insufficient.<\/p>\n<\/div>\n<div class=\"ins-faq-item\">\n<p class=\"ins-faq-q\"><strong>What is the difference between LEED and WELL certification?<\/strong><\/p>\n<p class=\"ins-faq-a\">LEED and WELL measure different things. LEED, from the U.S. Green Building Council, certifies environmental performance. LEED v5, released April 2025, organizes credits around decarbonization, quality of life, and ecological conservation. WELL, from the International WELL Building Institute, certifies occupant health, comfort, and wellbeing. Both include indoor air quality as a criterion, and many Jakarta projects pursue them together.<\/p>\n<\/div>\n<\/div>\n<h2 class=\"ins-h2\" id=\"acknowledgment\">Acknowledgment<\/h2>\n<p class=\"ins-p ins-ack\">This article draws on indoor air quality research originally contributed by Angela Michelle Sutopo (Universitas Multimedia Nusantara) during an internship with ALTA Integra.<\/p>\n<h2 class=\"ins-h2\" id=\"sources\">Sources<\/h2>\n<ol class=\"ins-sources\">\n<li>IQAir, &#8220;2020 World Air Quality Report,&#8221; 2020.<\/li>\n<li>D. R. Boyd, &#8220;The Human Right to Breathe Clean Air,&#8221; Annals of Global Health, 2019, vol. 85, no. 1.<\/li>\n<li>WHO, &#8220;Health for All in the 21st Century,&#8221; 1997.<\/li>\n<li>LEED, &#8220;LEED v4 User Guide,&#8221; U.S. Green Building Council, 2014.<\/li>\n<li>International WELL Building Institute, &#8220;The WELL Certification Guidebook,&#8221; 2021.<\/li>\n<li><a href=\"https:\/\/iris.who.int\/bitstream\/handle\/10665\/345329\/9789240034228-eng.pdf\" target=\"_blank\" rel=\"noopener\">WHO, Air Quality Guidelines: Global Update 2021<\/a> (particulate matter, ozone, nitrogen dioxide, sulfur dioxide), WHO, Geneva, 2021.<\/li>\n<li><a href=\"https:\/\/www.iqair.com\/us\/newsroom\/waqr-2024-pr\" target=\"_blank\" rel=\"noopener\">IQAir, &#8220;2024 World Air Quality Report&#8221;<\/a> for Jakarta annual PM2.5, 2024.<\/li>\n<li>M. Greenstone and Q. Fan, &#8220;Air Quality Life Index Update: Indonesia&#8217;s Worsening Air Quality and its Impact on Life Expectancy,&#8221; 2019.<\/li>\n<li>Bandung Institute of Technology, &#8220;Main Sources of Air Pollution in Jakarta&#8221; (Toyota Clean Air Project).<\/li>\n<li>BMKG, &#8220;Informasi Konsentrasi Partikulat (PM2.5).&#8221;<\/li>\n<li>S. Pramana, D. Y. Paramartha, Y. Adhinugroho, and M. Nurmalasari, &#8220;Air Pollution Changes of Jakarta, Banten, and West Java, Indonesia During the First Month of COVID-19 Pandemic,&#8221; Journal of Business, Economics and Environmental Studies, 2020, vol. 10, no. 4.<\/li>\n<li>E. R. Jones, J. G. Cede\u00f1o Laurent, A. S. Young, P. MacNaughton, B. A. Coull, J. D. Spengler, and J. G. Allen, &#8220;The Effects of Ventilation and Filtration on Indoor PM2.5 in Office Buildings in Four Countries,&#8221; Building and Environment, 2021, vol. 200.<\/li>\n<li><a href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC6481574\/\" target=\"_blank\" rel=\"noopener\">B. Haryanto and E. Pramitha, &#8220;Effect of Exposure to 2.5 &mu;m Indoor Particulate Matter on Adult Lung Function in Jakarta&#8221;<\/a>, Osong Public Health and Research Perspectives, 2019, vol. 10, no. 2.<\/li>\n<li>H. Park, S. Park, and J. Seo, &#8220;Evaluation on Air Purifier&#8217;s Performance in Reducing the Concentration of Fine Particulate Matter for Occupants According to its Operation Methods,&#8221; International Journal of Environmental Research and Public Health, 2020, vol. 17, no. 15.<\/li>\n<li><a href=\"https:\/\/aqli.epic.uchicago.edu\/files\/Indonesia%20FactSheet_2025.pdf\" target=\"_blank\" rel=\"noopener\">Energy Policy Institute at the University of Chicago (EPIC), &#8220;Air Quality Life Index \u2014 Indonesia Fact Sheet&#8221;<\/a>, AQLI Annual Update 2025 (2023 PM2.5 data).<\/li>\n<li><a href=\"https:\/\/www.usgbc.org\/leed\/v5\" target=\"_blank\" rel=\"noopener\">U.S. Green Building Council, &#8220;LEED v5&#8221;<\/a>, released April 2025. <a href=\"https:\/\/www.usgbc.org\/tools\/leed-certification\/deadlines\" target=\"_blank\" rel=\"noopener\">LEED v4\/v4.1 certification deadlines<\/a> (registration open through June 30, 2027).<\/li>\n<\/ol>\n<p><!--alta-seo-block--><\/p>\n<h2 id=\"related-work\" class=\"ins-h2\">Related Indoor Air Quality Insights and Project Work<\/h2>\n<p class=\"ins-p\">Further Indoor Air Quality material from ALTA Integra: related technical insights, and the built projects where this engineering was applied.<\/p>\n<ul class=\"ins-related\">\n<li><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/2026\/07\/01_bedroom-interior-with-open-window-pd3knrz_jpg.webp\" alt=\"Indoor Air Quality and Occupant Health: Pollutant Sources, Ventilation Rates and Verification : related indoor air quality work by ALTA Integra\" loading=\"lazy\" title=\"\"> <strong>Insight:<\/strong> <a href=\"https:\/\/altaintegra.com\/insight\/indoor-air-quality-and-occupant-health\/\">Indoor Air Quality and Occupant Health: Pollutant Sources, Ventilation Rates and Verification<\/a> covering four pollutant groups, four different control strategies, and why a building cannot assume it achieved good air just because it was designed with good intentions.<\/li>\n<li><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/2026\/07\/01_download_png.webp\" alt=\"Upper-Room UVGI: How Germicidal UV Disinfects Air in Occupied Rooms : related indoor air quality work by ALTA Integra\" loading=\"lazy\" title=\"\"> <strong>Insight:<\/strong> <a href=\"https:\/\/altaintegra.com\/insight\/upper-room-uvgi\/\">Upper-Room UVGI: How Germicidal UV Disinfects Air in Occupied Rooms<\/a> noting that the technology is eighty years old, the evidence is unusually good, and the standard governing it was published in 2023.<\/li>\n<li><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/2026\/07\/01_spanish_hacienda_jpg.webp\" alt=\"Bioclimatic Architecture as a Strategy for Green Buildings : related indoor air quality work by ALTA Integra\" loading=\"lazy\" title=\"\"> <strong>Insight:<\/strong> <a href=\"https:\/\/altaintegra.com\/insight\/bioclimatic-architecture-strategy\/\">Bioclimatic Architecture as a Strategy for Green Buildings<\/a> where bioclimatic architecture designs buildings to work with local climate rather than isolate against it, from ancient techniques to modern biomimicry.<\/li>\n<li><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/gbk-1-v2.jpg\" alt=\"Indoor Multi-Purpose Stadium Gelora Bung Karno : related indoor air quality work by ALTA Integra\" loading=\"lazy\" title=\"\"> <strong>Project:<\/strong> <a href=\"https:\/\/altaintegra.com\/project\/gelora-bung-karno-indoor-stadium\/\">Indoor Multi-Purpose Stadium Gelora Bung Karno<\/a> featuring acoustic design engineered for every spectator&#8217;s experience, with reduced echoes and consistent PA clarity across every seating tier.<\/li>\n<li><img decoding=\"async\" src=\"https:\/\/altaintegra.com\/wp-content\/uploads\/jp-morgan-1-v2.jpg\" alt=\"Global Investment Bank Head Office : related indoor air quality work by ALTA Integra\" loading=\"lazy\" title=\"\"> <strong>Project:<\/strong> <a href=\"https:\/\/altaintegra.com\/project\/global-investment-bank-jakarta-office\/\">Global Investment Bank Head Office<\/a> featuring daylight integration with artificial lighting, sDA \/ ASE analysis, and LEED-grade acoustics. The result delivers productivity without sterility.<\/li>\n<\/ul>\n<p><!--\/alta-seo-block--><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Jakarta&#8217;s annual average PM2.5 concentration was  [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":951,"template":"","meta":{"_acf_changed":false,"footnotes":""},"subsector":[],"stream":[108],"class_list":["post-950","insight","type-insight","status-publish","has-post-thumbnail","hentry","stream-knowledge"],"acf":[],"_links":{"self":[{"href":"https:\/\/altaintegra.com\/zh\/wp-json\/wp\/v2\/insights\/950","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/altaintegra.com\/zh\/wp-json\/wp\/v2\/insights"}],"about":[{"href":"https:\/\/altaintegra.com\/zh\/wp-json\/wp\/v2\/types\/insight"}],"author":[{"embeddable":true,"href":"https:\/\/altaintegra.com\/zh\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":5,"href":"https:\/\/altaintegra.com\/zh\/wp-json\/wp\/v2\/insights\/950\/revisions"}],"predecessor-version":[{"id":2237,"href":"https:\/\/altaintegra.com\/zh\/wp-json\/wp\/v2\/insights\/950\/revisions\/2237"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/altaintegra.com\/zh\/wp-json\/wp\/v2\/media\/951"}],"wp:attachment":[{"href":"https:\/\/altaintegra.com\/zh\/wp-json\/wp\/v2\/media?parent=950"}],"wp:term":[{"taxonomy":"subsector","embeddable":true,"href":"https:\/\/altaintegra.com\/zh\/wp-json\/wp\/v2\/subsector?post=950"},{"taxonomy":"stream","embeddable":true,"href":"https:\/\/altaintegra.com\/zh\/wp-json\/wp\/v2\/stream?post=950"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}