One of the requirements set for this is the achievement of the NC-25 noise criteria. To achieve NC-25, we carried out several studies starting from observing environmental noise, observing building construction and materials to be installed.
In addition, we also expect the reverberation on the indoor stage to be under 1.5 seconds. We perform Acoustic Modeling simulations to predict the reverberations that will occur in the room.